Hypofractionation

Patient motion matters - more than ever

Hypofractionated radiation therapy – increasing the dose per fraction to enable fewer treatments — has emerged as one way for clinics to provide the same outcomes for patients, with certain tumors, enabling a more convenient patient experience whilst reducing the cost burden for the hospital. Being able to confidently deliver the highest level of accuracy is critical to the success of this protocol, to ensure the best possible patient outcomes. AlignRT® tracks patient motion in real-time in all 6 degrees of freedom with sub-half millimetric accuracy | ≤ 0.3 mm / 0.2°¹.  Elevating patient safety, the system can automatically signal treatment to pause if the patient moves out of position.

Horizon right

Hypofractionate with confidence

Hypofractionation; delivering higher doses over fewer fractions with reduced clinical margins, can raise key concerns around safety and accuracy. AlignRT®, the Surface Guided Radiation Therapy (SGRT) solution from Vision RT, can help you ensure these additional demands are met and you can be confident treatment is delivered exactly as planned.

Automatic beam-hold

With AlignRT, the beam will be held if the patient moves out of position – even momentarily.

Hey! I am first heading line feel free to change me

Treatment versatility

AlignRT can be used on every patient, for every fraction on sites from head to toe.

Hey! I am first heading line feel free to change me

Increased patient comfort

No invasive frames or closed masks, with the option for tattoo and mark-free treatment.

Get in touch to learn more about how AlignRT can help you hypofractionate with confidence.

Use the form on the right and let us know if you’d like to schedule a demo (virtual or in-person), receive a brochure, get a quote from a member of our sales team, or find out more about our business case and marketing support. 

I’d like to schedule a virtual demo for:

Find out more about patient education resources and business support in your area.

I would like an e-brochure for:

I would like a quote for:

REFERENCES

  1. Wen et at. Technical Note: Evaluation of the systematic accuracy of a frameless, multiple image modality guided, linear accelerator based stereotactic radiosurgery system. Med Phys. 2016 May;43(5):2527
    Covington E, et al. Submillimeter monitoring of intrafraction patient movement with optical surface imaging. AAPM Annual Meeting 2018.
  2. Menyhart G. SGRT for Breath Hold SBRT: A Measured Response. SGRT Annual Meeting, Atlanta 2016
    Lawson J. Surface Guided Radiation Therapy (SGRT) in SRS and SBRT. Advances in Accuracy and Elevating Patient Experience, Sydney 2019